VOLUME SENSOR VCA0,04

DP-K-011-000002


  • Visual grease volume monitoring
  • Measuring range 0.004–4.00 l/min
  • Low flow resistances
  • Any direction of flow
  • High compressive strength




DESCRIPTION

The flow meter measures the moving dosing volume of liquids according to the gearwheel principle. A pair of gears fitted very precisely into the housing forms the measuring mechanism. The rotation of the measuring mechanism is detected tooth by tooth without contact by a signal pickup system and converted into digital pulses.

The integrated transducer with PNP outlet generates a pulse per tooth with a valence of 0.04 cm³.

The pulse frequency is proportional to the speed of the meter wheels, which are driven by the volume flow.




Technical Data

Measuring range
0.004–4.00 l/min

Impulses
25,000/l

Volume per impulse
0.04 cm³

Pmax
200 bar

Tmax
80 °C

Supply
10–30 V DC ± 10 %

Connection
G 1/4" lateral

Output
PNP / NPN circuit

Adapter plug
DIN 43650A-M12

expand_more Show more...