VOLUME SENSOR VC0,025

DP-K-011-000003


  • Visual grease volume monitoring
  • Measuring range 0.008–2 l/min
  • Low flow resistances
  • Any direction of flow
  • High compressive strength




DESCRIPTION

The measuring mechanism, which consists of two high-precision gear wheels, is driven by the liquid flow according to the displacement principle.

The gears run almost contactless in the measuring chamber. Low-friction ball or plain bearings serve as bearing elements. Due to the measuring principle, no settling sections are necessary at the inlet and outlet.
This means that machines/plants can be designed more compactly. All moving parts are lubricated by the measuring medium.

The movement of the gearwheel is scanned contactlessly by two sensors in the cover as standard. When the measuring mechanism rotates by one tooth pitch, a signal is generated per sensor which corresponds to the so-called geometric tooth volume Vgz. The two-channel scanning enables a higher measured value resolution as well as a directional recognition of the flow.




Technical Data

Specific data

Flow measuring range
0.008–2 l/min

Measuring unit start-up
at 0.001 l/min

Linearised measurement accuracy
± 0.3 % of the measured value
(at viscosity: min. 20 mm²/s)

Repeatability
± 0.05 %

Resolution
40,000 pulses/l

Max. perm. pressure
200 bar

Operating fluid temperature
–15–120°C

Ambient temperature
–15–80°C

Max. foreign particle size
20 μm

Electrical data

Pulse volume
0.025 cm³/pulse

Line connection Pipe connection
G 1/8"

Electronic output
2 square-wave signals, 90° offset

Electrical connection
Plastic angle plug – terminal strip
Standard temperature version

Supply voltage
24 V DC ± 20 %

Materials

Material housing
Ductile cast iron EN-GJS 400

Material measuring unit
Steel 1.7139

Material O-rings
FKM

Bearing
Ball bearing

expand_more Show more...